KOALA MINERS
Huapeng 3000 KVA Pad Mounted Transformer.
Huapeng 3000 KVA Pad Mounted Transformer.
Couldn't load pickup availability
📦 Free worldwide shipping on all orders.
🔌 Power Supply (PSU) and all cables included
🛡️ 30-day buyer protection & free returns.
✓ Capacity: 3000 kVA
✓ Phase: Three-phase
✓ Impedance: 5.75%
✓ Cooling: KNAN with FR3 oil
✓ Vector Group: Dyn1
✓ Efficiency: DOE-2016 compliant
✓ High Voltage: 12,470 Delta Volts, 95 kV BIL
✓ High Voltage Configuration: Dead Front, Loop Feed
✓ Taps: 2 – 2.5% taps above and 2 – 2.5% taps below normal
✓ Load-Break Switching: 15-38kV, 200A
✓ Overcurrent Protection: Bayonet Fuses with Partial-Range Current-Limiting Fuses
✓ Low Voltage: 415 Volts, 30 kV BIL
✓ Low Voltage Class: 1.2 kV
✓ Coatings: Munsell Green topcoat
Transformer Specifications:
The Huapeng 3000kVA Pad Transformer is a robust three-phase transformer with a capacity of 3000 kVA, making it suitable for various industrial and utility applications. Its low impedance of 5.75% ensures efficient power transfer while minimizing energy losses. This transformer operates with a cooling system consisting of KNAN and FR3 oil, guaranteeing effective temperature control. Its Dyn1 vector group configuration provides flexibility in power distribution setups, and it complies with DOE-2016 efficiency standards, reflecting its commitment to energy efficiency. With high voltage rated at 12,470 Delta Volts and a 95 kV BIL, it can handle demanding voltage requirements. The inclusion of multiple taps, both above and below the normal rating, allows for precise voltage adjustments, ensuring optimal performance. Additionally, its load-break switching capability at 15-38kV and 200A provides versatility in managing electrical circuits.
Safety and Accessories:
The Huapeng 3000kVA Pad Transformer prioritizes safety and reliability. It features overcurrent protection using bayonet fuses in series with Partial-Range Current-Limiting fuses, minimizing the risk of electrical faults. With a low voltage rating of 415 Volts and a 30 kV BIL, it provides consistent power distribution on the low-voltage side. The transformer is equipped with IEEE standard two-hole ground pads for grounding, enhancing safety. Its construction includes a durable enclosure with a bolted or welded cover, ensuring the security of internal components. The presence of gauges, including liquid level, thermometer, pressure/vacuum gauge, and a drain valve with a sampler in the low-voltage compartment, offers real-time monitoring and maintenance convenience. Lastly, the Munsell Green topcoat adds a protective layer to the transformer's exterior while adhering to industry standards.